Tempest orbital cleaner
Extremely powerful, radially and axially rotating jet cleaner with 4 nozzles
- fluid powered 360° low pressure orbital cleaner
- extremely strong jet strength and high flow rate
- FDA compliant & EX certified
- acid, alkali and temperature resistant
- compact dimensions
- self-cleaning, hygienic, low-wear
- validatable cleaning
- Function monitoring by Vericlean or SMW 100
Technical Data | Value |
---|---|
Max. cleaning diameter: | 19 meters |
Spray pattern: | 360° orbital |
Pressure range: | 4 – 10 bar / 58-145 psi |
Flow rate: | 200 – 410 lpm (12,0 – 24,6 m³/h) |
Insertion opening: | min. Ø 210 mm |
Preferred mounting position: | arbitrary, preferrably vertical |
Weight: | approx. 3,9 KG |
Materials: | Stainless Steel 316L 316L (1.4404), C.PTFE, PTFE, C.PEEK |
Pipe connection: | 1,5″ female thread BSP (NPT) |
Optional Pipe Connections: | 1,5″ Splint, DN40 Splint, DN50 Splint, 1,5″ Clamp |
Nozzle characteristics: | 4 x 7,0 mm nozzles, 4 x 8 mm nozzles, 4 x 9 mm nozzles |
Certificates: | 3.1, 2.2, ATEX, FDA Regulation (EC) No 1935/2004 |
Max. operating temperature: | 95°C (203°F) |
Max. ambient temperature: | 140°C (284°F), 30 Min. |
Operating recommendation: | It is recommended to install a filter/strainer (500 μm) in the CIP supply line to the tank cleaner to protect it from particle clogging or damage. |
The Tempest is a powerful target jet cleaner with an orbital 360° spray pattern. The Tempest is driven by the cleaning medium at a pressure of 4 to 8 bar. Turbine-driven, a radial and axial rotation of the nozzle head is generated. This creates aligned jets of liquid through four long nozzles with a strong impact effect up to a diameter of 19 metres. By circulating jets of liquid, a completing spray pattern with high coverage and full coverage is thus produced within 5 to 9.5 minutes.
Thanks to optimal flow control, a smooth-running mechanism without ball bearings and a hygienic sealing concept, the energy used on the unit is transformed into a powerful cleaning effect. The orbital cleaning behaviour enables the best possible use of the cleaning liquid or chemical additives. For use in hygiene-sensitive areas, the unit keeps itself permanently clean with a self-cleaning nozzle and empties itself automatically after use in vertical operation.
The use of the unit always conserves resources and requires minimal wear and maintenance. The Tempest meets the highest hygiene and safety standards and can be used in EX zones and FDA applications at the same time. During a long service life, this unit will always prove to be a reliable partner for your cleaning tasks. Tempest orbital cleaners are available in many connection variants. Optionally, the cleaning process of a Tempest can be permanently and non-invasively monitored by SMW 100 or Vericlean. The Tempest is one of the latest and most effective developments in the cleaning technology market.
Tempest orbital cleaners are available with many connection variants. is very compact and can be installed in any position in vessels or equipment using a 1,5” threaded connection or a choice of cotter pin or clamp mounting. It can also be used on a lance or hanging from a hose. Frequent areas of application for this product are tanks and containers in the brewing, beverage, dairy processing, food, pharmaceutical, chemical and transport industries as well as on ships.
Connection types
Threaded connection
Tempest standard devices are equipped with a 1,5″ cylindrical internal thread BSP (British Standard PIPE according to DIN ISO 228). The device is optionally available with a 1,5″ conical internal thread NPT (National Pipe Taper, American pipe thread for self-sealing connections).
Splint connection
The Tempest orbital cleaner is optionally available with a 1,5″, DN40 or DN50 splint pin attachment. The splint pin attachment ensures that the cleaning machine is attached without dead space. Splint pin versions have an approx. 15% higher flow rate.
Clamp connection
The Tempest is optionally available with a 1,5″ clamp connection. A clamp connection ensures the uncomplicated removal of the cleaning machine.
Tempest BSP Threaded connection
Attachment | Nozzles | Pipe* | Product code | Materials | Certificates | Article Number |
---|---|---|---|---|---|---|
*corresponds to the maximum pipe OD of the pipe on which the machine is to be installed (inches or mm). Splint pin versions have an approx. 15% higher flow rate. Recommended standard devices with a high probability of being in stock are set in blue. | ||||||
1,5″ IG-BSP | 4 x 7,0 mm | 1,5″ | Tempest-AF4x7S-BSP | 316L/C.PTFE | ATEX+FDA, 3.1 | 4660-4968-117 |
1,5″ IG-BSP | 4 x 7,0 mm | 1,5″ | Tempest-F4x7S-BSP | 316L/PTFE | FDA, 3.1 | 4660-4968-119 |
1,5″ IG-BSP | 4 x 7,0 mm | 1,5″ | Tempest-AF4x7S-NPT | 316L/C.PTFE | ATEX+FDA, 3.1 | 4660-4968-121 |
1,5″ IG-BSP | 4 x 7,0 mm | 1,5″ | Tempest-F4x7S-NPT | 316L/PTFE | FDA, 3.1 | 4660-4968-123 |
1,5″ IG-BSP | 4 x 8,0 mm | 1,5″ | Tempest-AF4x8S-BSP | 316L/C.PTFE | ATEX+FDA, 3.1 | 4660-4968-118 |
1,5″ IG-BSP | 4 x 8,0 mm | 1,5″ | Tempest-F4x8S-BSP | 316L/PTFE | FDA, 3.1 | 4660-4968-120 |
1,5″ IG-BSP | 4 x 8,0 mm | 1,5″ | Tempest-AF4x8S-NPT | 316L/C.PTFE | ATEX+FDA, 3.1 | 4660-4968-122 |
1,5″ IG-BSP | 4 x 8,0 mm | 1,5″ | Tempest-F4x8S-NPT | 316L/PTFE | FDA, 3.1 | 4660-4968-124 |
1,5″ IG-BSP | 4 x 9,0 mm | 1,5″ | Tempest-AF4x9S-BSP | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
1,5″ IG-BSP | 4 x 9,0 mm | 1,5″ | Tempest-F4x9S-BSP | 316L/PTFE | FDA, 3.1 | – |
1,5″ IG-BSP | 4 x 9,0 mm | 1,5″ | Tempest-AF4x9S-NPT | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
1,5″ IG-BSP | 4 x 9,0 mm | 1,5″ | Tempest-F4x9S-NPT | 316L/PTFE | FDA, 3.1 | – |
Tempest with 1,5″ Splint attachment
Attachment | Nozzles | Pipe* | Product code | Materials | Certificates | Article Number |
---|---|---|---|---|---|---|
*corresponds to the maximum pipe OD of the pipe on which the machine is to be installed (inches or mm). Splint pin versions have an approx. 15% higher flow rate. Recommended standard devices with a high probability of being in stock are set in blue. | ||||||
1,5″ Splint | 4 x 7,0 mm | 38,1 | Tempest-AF4x7S-150PF | 316L/C.PTFE | ATEX+FDA, 3.1 | 4660-4968-125 |
1,5″ Splint | 4 x 7,0 mm | 38,1 | Tempest-F4x7S-150PF | 316L/PTFE | FDA, 3.1 | 4660-4968-127 |
1,5″ Splint | 4 x 8,0 mm | 38,1 | Tempest-AF4x8S-150PF | 316L/C.PTFE | ATEX+FDA, 3.1 | 4660-4968-126 |
1,5″ Splint | 4 x 8,0 mm | 38,1 | Tempest-F4x8S-150PF | 316L/PTFE | FDA, 3.1 | 4660-4968-128 |
1,5″ Splint | 4 x 9,0 mm | 38,1 | Tempest-AF4x9S-150PF | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
1,5″ Splint | 4 x 9,0 mm | 38,1 | Tempest-F4x97S-150PF | 316L/PTFE | FDA, 3.1 | – |
Tempest with DN40 Splint attachment
Attachment | Nozzles | Pipe* | Product code | Materials | Certificates | Article Number |
---|---|---|---|---|---|---|
*corresponds to the maximum pipe OD of the pipe on which the machine is to be installed (inches or mm). Splint pin versions have an approx. 15% higher flow rate. Recommended standard devices with a high probability of being in stock are set in blue. | ||||||
DN40 Splint | 4 x 7,0 mm | 41,15 | Tempest-AF4x7S-DN40 | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
DN40 Splint | 4 x 7,0 mm | 41,15 | Tempest-F4x7S-DN40 | 316L/PTFE | FDA, 3.1 | – |
DN40 Splint | 4 x 8,0 mm | 41,15 | Tempest-AF4x8S-DN40 | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
DN40 Splint | 4 x 8,0 mm | 41,15 | Tempest-F4x8S-DN40 | 316L/PTFE | FDA, 3.1 | – |
DN40 Splint | 4 x 9,0 mm | 41,15 | Tempest-AF4x9S-DN40 | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
DN40 Splint | 4 x 9,0 mm | 41,15 | Tempest-F4x9S-DN40 | 316L/PTFE | FDA, 3.1 | – |
Tempest with DN50 Splint attachment
Attachment | Nozzles | Pipe* | Product code | Materials | Certificates | Article Number |
---|---|---|---|---|---|---|
*corresponds to the maximum pipe OD of the pipe on which the machine is to be installed (inches or mm). Splint pin versions have an approx. 15% higher flow rate. Recommended standard devices with a high probability of being in stock are set in blue. | ||||||
DN50 Splint | 4 x 7,0 mm | 53,25 | Tempest-AF4x7S-DN50 | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
DN50 Splint | 4 x 7,0 mm | 53,25 | Tempest-F4x7S-DN50 | 316L/PTFE | FDA, 3.1 | – |
DN50 Splint | 4 x 8,0 mm | 53,25 | Tempest-AF4x8S-DN50 | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
DN50 Splint | 4 x 8,0 mm | 53,25 | Tempest-F4x8S-DN50 | 316L/PTFE | FDA, 3.1 | – |
DN50 Splint | 4 x 9,0 mm | 53,25 | Tempest-AF4x9S-DN50 | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
DN50 Splint | 4 x 9,0 mm | 53,25 | Tempest-F4x9S-DN50 | 316L/PTFE | FDA, 3.1 | – |
Tempest mit 1,5″ Clamp attachment
Attachment | Nozzles | Pipe* | Product code | Materials | Certificates | Article Number |
---|---|---|---|---|---|---|
*corresponds to the maximum pipe OD of the pipe on which the machine is to be installed (inches or mm). Splint pin versions have an approx. 15% higher flow rate. Recommended standard devices with a high probability of being in stock are set in blue. | ||||||
1,5″ Clamp | 4 x 7,0 mm | 1,5″ | Tempest-AF4x7S-150CL | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
1,5″ Clamp | 4 x 7,0 mm | 1,5″ | Tempest-F4x7S-150CL | 316L/PTFE | FDA, 3.1 | – |
1,5″ Clamp | 4 x 8,0 mm | 1,5″ | Tempest-AF4x8S-150CL | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
1,5″ Clamp | 4 x 8,0 mm | 1,5″ | Tempest-F4x8S-150CL | 316L/PTFE | FDA, 3.1 | – |
1,5″ Clamp | 4 x 9,0 mm | 1,5″ | Tempest-AF4x9S-150CL | 316L/C.PTFE | ATEX+FDA, 3.1 | – |
1,5″ Clamp | 4 x 9,0 mm | 1,5″ | Tempest-F4x9S-150CL | 316L/PTFE | FDA, 3.1 | – |
Accessories
Welded adapter
Materials: | Stainless steel 1.4404 (316L) |
Certificates: | 3.1, 2.2 |
Device attachment: | 1,5″ AG-BSP |
Supply: | Welding end |
SMW 100 Fluid sensor
Materials: | 1.4305, PEEK |
Connecton type: | Welded socket |
Function: | Sensor surge is displayed every 20 seconds. |
Maintenance packages & Toolkit
Tempest C.PTFE (ATEX & FDA) | 4660-4050-888 |
Tempest PTFE (FDA) | 4660-4051-888 |
Toolkit: | 4660-4031-888 |
The data, technical data and information presented do not release the user from the obligation to check the suitability of the products supplied for the intended application. All information is without guarantee. (Status of: 17.10.2022-71427321893-1888948-71042)